RECOMMENDED PRESSURES FOR GROUTING
TRADITIONAL UNITS
| Depth to Bottom of stage |
PRESSURES at surface |
| Average Rock |
Sound Rock |
Weak Rock |
| (feet) |
(psi) |
(psi) |
(psi) |
| 5 |
5 |
10 |
5 |
| 10 |
15 |
20 |
5 |
| 15 |
20 |
35 |
10 |
| 20 |
25 |
45 |
15 |
| 25 |
35 |
60 |
20 |
| 30 |
40 |
70 |
25 |
| 35 |
45 |
80 |
30 |
| 40 |
55 |
95 |
30 |
| 45 |
60 |
105 |
35 |
| 50 |
65 |
115 |
40 |
| 55 |
70 |
125 |
45 |
| 60 |
75 |
140 |
50 |
| 65 |
85 |
145 |
50 |
| 70 |
90 |
160 |
55 |
| 75 |
110 |
170 |
60 |
| 80 |
105 |
180 |
65 |
| 85 |
110 |
190 |
70 |
| 90 |
120 |
200 |
70 |
| 95 |
125 |
200 |
75 |
| 100 |
130 |
200 |
80 |
| 105 |
135 |
200 |
85 |
| 110 |
145 |
200 |
85 |
| 115 |
150 |
200 |
90 |
| 120 |
150 |
200 |
95 |
| 125 |
150 |
200 |
100 |
| 130 |
150 |
200 |
105 |
| 135 |
150 |
200 |
110 |
| 140 |
150 |
200 |
110 |
| 145 |
150 |
200 |
115 |
| 150 |
150 |
200 |
120 |
| 150 |
150 |
200 |
120 |